How to Test a Pressure Canner Gauge
Dial gauges drift. Since your safety depends on the pressure the dial says, it has to be checked.
Have a dial gauge tested every year before canning season and after any drop, usually at a county extension office or through the canner's maker, and replace it if it reads more than 2 pounds off at 5, 10 or 15 pounds.

When to test
- Once a year before you start canning.
- After the canner or lid is dropped.
- If the glass is cracked, the needle doesn't rest at zero, or there's rust.
- After the gauge has been submerged.
Where to get it tested
Call your county Cooperative Extension office; many test common gauges, especially Presto, for free or a small fee. Presto also offers testing for its gauges. Bring only the lid.
If it's off
NCHFP's guidance: if it reads off by less than 2 pounds at 5, 10 or 15 pounds, you can adjust your processing pressure to compensate; if it's more than 2 pounds off, replace it. Replacement gauges are inexpensive.
Weighted gauges
Weighted regulators don't need testing. Keep the vent pipe clear and the weight undamaged. That's a big reason some people prefer the Granite Ware 20-Quart or Presto's 3-piece regulator.
Questions
Can I test a gauge at home?
Not reliably. Testers compare the gauge to a certified master gauge. Use an extension office or the maker.
Does a weighted-gauge canner need testing?
No. Canners like the Granite Ware 20-Quart go by a weight, which can't drift out of calibration.